PLC, PAC and Dedicated Controllers
Schneider Electric TM3SAFL5R Safety module, Modicon TM3 Safety, 2 Function, Cat 3 PL d/SIL CL2 (screw) 24 VDC

Schneider Electric TM3SAFL5R Safety module, Modicon TM3 Safety, 2 Function, Cat 3 PL d/SIL CL2 (screw) 24 VDC

Model: TM3SAFL5R

Supplier: Schneider Electric

Categories: PLC, PAC and Dedicated Controllers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Schneider Electric TM3SAFL5R Safety module, Modicon TM3 Safety, 2 Function, Cat 3 PL d/SIL CL2 (screw) 24 VDC

Safety module.JPG

Main

Range of product Modicon TM3 Safety

Product or component type Safety module

Device short name TM3SAFL

Safety module application For emergency stop, switch and safety light curtain monitoring

Function of module Emergency stop monitoring 2-channel wiring

Monitoring of a movable guard with 2 switches and automatic start

Monitoring of a movable guard

Multiple emergency stop monitoring 2-channel wiring

Proximity sensor monitoring PNP/PNP

Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP

Safety level Can reach PL d/category 3 conforming to EN/ISO 13849-1: 2008

Can reach PL d/category 3 conforming to EN/ISO 13849-2: 2012

Can reach SILCL 2 conforming to EN/IEC 62061: 2005

Can reach SIL 2 conforming to EN/IEC 61508: 2010

Complementary

Safety reliability data DC = 95 % conforming to EN/ISO 13849-1

PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A

PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A

MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A

MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A

SFF = 95 % conforming to IEC 61508-1

HFT = 1 conforming to IEC 61508-1

Type = A conforming to IEC 61508-1

Synchronisation time between inputs Unlimited

Connections - terminals Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals

Output type Relay instantaneous opening, 3 NO circuit(s), potential free

Number of safety circuits 3 NO for relay instantaneous opening

Maximum switching voltage 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)

24 V utilisation category DC-13 (relay instantaneous opening)

[Us] rated supply voltage 24 V - 15...20 % DC

Power consumption in W 0.2 W at 5 V DC

3.6 W at 24 V DC

Input protection type Internal, electronic

[Uc] control circuit voltage 24 V DC

Maximum cable distance between devices 30 m

Breaking capacity 360 VA holding AC-15 B300 relay output

3600 VA inrush AC-15 B300 relay output

Breaking capacity 4 A 24 V 50 ms DC-13 relay output

Output thermal current 6 A per relay for relay output

[Ith] conventional free air thermal current 18 A

Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1

6 A fast blow for relay output conforming to EN/IEC 60947-5-1

Minimum output current 10 mA for relay output

Output voltage 10 V relay output

Maximum response time on input open 40 ms

[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60647-5-1

[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1

Current consumption 100 mA at 24 V DC external supply

Local signalling 8 LEDs (green/red) for user

Electrical connection Screw terminal

Product compatibility Safety light curtains conforming to EN/IEC 61496-1 (type 4)

Standards EN/ISO 13849-1:2008

EN/ISO 13849-2:2012

EN/IEC 62061:2005

EN/IEC 61508:2010

EN/IEC 60947-5-1:2010

EN/IEC 61131-2:2007

EN/IEC 60204-1:2005

EN/IEC 60204-1:2009/A1

IEC 61010-1:2010

EN 50581:2012

Product certifications TÜV

RCM

ANSI Haz Loc Class 1 Division 2 (pending)

CSA Haz Loc Class 1 Division 2 (pending)

EAC

CSA 61010-2-201 (pending)

UL 61010-2-201

Marking CE

EFUP 10

UL

CSA

EAC

RCM

TÜV

Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2

Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2

Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3

Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3

Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3

Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8

Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4

1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5

Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6

Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011

Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011

Mounting support Top hat type TH35-7.5 rail conforming to IEC 60715

Top hat type TH35-15 rail conforming to IEC 60715

wall mount using attached fasteners

Height 94 mm

Depth 73 mm

Width 43.7 mm

Net weight 0.19 kg

Environment

Standards EN/IEC 60947-1

EN 1088/ISO 14119

EN/ISO 13850

EN/IEC 60947-5-1

EN 60204-1

Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2

6 kV on contact conforming to EN/IEC 61000-4-2

Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3

3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3

1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3

Resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8

Resistance to fast transients 3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4

2 kV for I/O lines conforming to EN/IEC 61000-4-4

Surge withstand 1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC

1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC

Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6

Electromagnetic emission Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3

Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3

Ambient air temperature for operation -10…55 °C horizontal installation

Ambient air temperature for storage -25…70 °C

Relative humidity 10…95 %, without condensation (in operation)

10…95 %, without condensation (in storage)

IP degree of protection IP20 (terminals) conforming to EN/IEC 60529

Pollution degree 2

Operating altitude 0...2000 m

Storage altitude 0…3000 m

Vibration resistance +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6

Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27

Mechanical robustness Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 7.5 cm

Package 1 Width 10.6 cm

Package 1 Length 12.5 cm

Package 1 Weight 277.0 g

Unit Type of Package 2 S03

Number of Units in Package 2 18

Package 2 Height 30.0 cm

Package 2 Width 30.0 cm

Package 2 Length 40.0 cm

Package 2 Weight 5.434 kg

Similar model numbers:

TM3SAC5R

TM3SAC5RG

TM3SAF5R

TM3SAF5RG

TM3SAFL5R

TM3SAFL5RG

TM3SAK6R

TM3SAK6RG


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods