Low-voltage Electrical Distribution Products and Systems
Schneider Electric GV3P186 Motor circuit breaker, TeSys Deca, 3P, 12 to 18A, thermal magnetic, lugs or bars terminals

Schneider Electric GV3P186 Motor circuit breaker, TeSys Deca, 3P, 12 to 18A, thermal magnetic, lugs or bars terminals

Model: GV3P186

Supplier: Schneider Electric

Categories: Low-voltage Electrical Distribution Products and Systems

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Schneider Electric GV3P186 Motor circuit breaker, TeSys Deca, 3P, 12 to 18A, thermal magnetic, lugs or bars terminals

Motor Circuit Breaker3.JPG

Main

Range TeSys Deca

Product name TeSys GV3

TeSys Deca

Product or component type Motor circuit breaker

Device short name GV3P

Device application Motor protection

Trip unit technology Thermal-magnetic

Complementary

Poles description 3P

Network type AC

Utilisation category AC-3 conforming to IEC 60947-4-1

Network frequency 50/60 Hz conforming to IEC 60947-4-1

Fixing mode 35 mm symmetrical DIN rail: clipped

Panel: screwed (with 3 x M4 screws)

Motor power kW 7.5 kW at 400/415 V AC 50/60 Hz

9 kW at 500 V AC 50/60 Hz

15 kW at 690 V AC 50/60 Hz

Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2

100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2

50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2

100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2

100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2

50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2

50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Control type Rotary handle

[In] rated current 18 A

Thermal protection adjustment range 12…18 A conforming to IEC 60947-4-1

Magnetic tripping current 252 A

[Ith] conventional free air thermal current 18 A conforming to IEC 60947-4-1

[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2

Phase failure sensitivity Yes conforming to IEC 60947-4-1

Suitability for isolation Yes conforming to IEC 60947-1

Power dissipation per pole 8 W

Mechanical durability 50000 cycles

Electrical durability 50000 cycles for AC-3 at 415 V In

Rated duty Continuous conforming to IEC 60947-4-1

Tightening torque 6 N.m - on lugs-ring terminals

Width 55 mm

Height 132 mm

Depth 136 mm

Net weight 0.96 kg

Colour Dark grey

Connection pitch 17.5 mm without spreaders

Environment

Standards EN/IEC 60947-2

EN/IEC 60947-4-1

UL 60947-4-1

CSA C22.2 No 60947-4-1

Product certifications CCC

UL

CSA

EAC

ATEX

LROS (Lloyds register of shipping)

BV

ABS

DNV-GL

UKCA

IK degree of protection IK09 enclosure

IP degree of protection IP20 conforming to IEC 60529

Climatic withstand Conforming to IACS E10

Ambient air temperature for storage -40…80 °C

Fire resistance 960 °C conforming to IEC 60695-2-11

Ambient air temperature for operation -20…60 °C

Mechanical robustness Shocks: 15 Gn for 11 ms contactor open

Shocks: 30 Gn for 11 ms contactor closed

Vibrations: 4 Gn, 5...300 Hz

Operating altitude 3000 m

Packing Units

Unit Type of Package 1 PCE

Number of Units in Package 1 1


Similar model numbers:

GV3P40

GV3P50

GV3P65

GV3P80

GV3P32

GV3P25

GV3P73

GV3L40

GV3L50

GV3L65

GV3P18

GV3P13

GV3L32

GV3L25

GV3L80

GV3P651

GV3P501

GV3L326

GV3P401

GV3L73

GV3P656

GV3P506

GV3P406

GV3P321

GV3P326

GV3P731

GV3P736

GV3P131

GV3P256

GV3P136

GV3P186

GV3L731

GV3L736


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods