In Stock Schneider Electric GV3P401 Motor circuit breaker, TeSys Deca frame 3, 3P, 30-40A, thermal magnetic, EverLink, without downstream
May 06, 2023In Stock Schneider Electric GV3P401 Motor circuit breaker, TeSys Deca frame 3, 3P, 30-40A, thermal magnetic, EverLink, without downstream
In Stock Schneider Electric GV3P401 Motor circuit breaker, TeSys Deca frame 3, 3P, 30-40A, thermal magnetic, EverLink, without downstream
jeff@hkxytech.com jeff@whxyauto.com +86-15072331761
Main
Range TeSys Deca
Product name TeSys GV3
TeSys Deca
Product or component type Motor circuit breaker
Device short name GV3P
Device application Motor protection
Trip unit technology Thermal-magnetic
Complementary
Poles description 3P
Network type AC
Utilisation category AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW 18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control type Rotary handle
[In] rated current 40 A
Thermal protection adjustment range 30…40 A conforming to IEC 60947-4-1
Magnetic tripping current 560 A
[Ith] conventional free air thermal current 40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles for AC-3 at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 5 N.m - on screw clamp terminal
Width 55 mm
Height 132 mm
Depth 136 mm
Net weight 0.96 kg
Colour Dark grey
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protection IK09 enclosure
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand Conforming to IACS E10
Ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.500 cm
Package 1 Width 16.000 cm
Package 1 Length 14.700 cm
Package 1 Weight 909.000 g
Unit Type of Package 2 P06
Number of Units in Package 2 60
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 67.540 kg
In Stock Schneider Electric GV3P401 Motor circuit breaker, TeSys Deca frame 3, 3P, 30-40A, thermal magnetic, EverLink, without downstream
jeff@hkxytech.com jeff@whxyauto.com +86-15072331761
Similar model numbers:
KFD2-CRG2-Ex1.D
KFD2-GUT-Ex1.D
KFU8-CRG2-Ex1.D
KFU8-GUT-Ex1.D
KFD2-WAC2-Ex1.D
KFD2-WAC2-Ex1.D-Y1
In Stock Schneider Electric GV3P401 Motor circuit breaker, TeSys Deca frame 3, 3P, 30-40A, thermal magnetic, EverLink, without downstream
jeff@hkxytech.com jeff@whxyauto.com +86-15072331761