News
News

In Stock Pepperl+Fuchs KFD2-SCD2-Ex1.LK SMART Current Driver

News April 12, 2023

In Stock Pepperl+Fuchs KFD2-SCD2-Ex1.LK SMART Current Driver

KFD2-SCD2-EX1.LK.JPG

In Stock Pepperl+Fuchs KFD2-SCD2-Ex1.LK SMART Current Driver

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761


General specifications

Signal typeAnalog output

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 14+, 15-

Rated voltage19 ... 30 V DC

Ripple≤ 10 %

Rated current≤ 30 mA at 24 V

Power dissipation≤ 600 mW at 20 mA and 500 Ω load

Power consumption≤ 700 mW

Input

Connection sidecontrol side

Connectionterminals 7-, 8+, (9+)

Input signal4 ... 20 mA , limited to approx. 30 mA

Input voltageopen loop voltage of the control system ≤ 30 V

Voltage dropapprox. 6 V at 20 mA

Input resistancefield wiring open circuit : > 100 kΩ

field wiring < 50 Ω : > 100 kΩ when using terminals 1 and 2

Output

Connection sidefield side

Connectionterminals 1+, 2-

terminals 3+, 2- (no short circuit detection)

Voltage≥ 13 V at 20 mA

Current4 ... 20 mA

Load100 ... 650 Ω , for terminals 1, 2

0 ... 550 Ω , for terminals 2, 3

Ripple20 mV rms

Line fault detectionbreakage, load > 100 kΩ, short-circuit, load < 50 Ω

Fault indication output

Output typeopen collector transistor (internal fault bus)

Transfer characteristics

Deviationat 20 °C (68 °F), 4 ... 20 mA

< 0.1 % of full scale, incl. non-linearity and hysteresis

Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F))

Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)

control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)

Rise time10 to 90 % ≤ 10 ms

Galvanic isolation

Input/Outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Input/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs

Labelingspace for adhesive label at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017

EN 61326-3-2:2018

Degree of protectionIEC 60529

Protection against electrical shockUL 61010-1:2012

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20

Connectionscrew terminals

Massapprox. 115 g

Dimensions20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) (W x H x D) , housing type B2

Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001


In Stock Pepperl+Fuchs KFD2-SCD2-Ex1.LK SMART Current Driver

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761


Similar model numbers:

KFD0-CS-Ex1.51P

KFD0-SCS-Ex1.55

KFD2-SCD2-Ex1.LK

KFD2-SCD2-Ex2.LK

KFD0-CS-Ex1.50P

KFD0-CS-Ex2.50P

KFD0-CS-Ex2.51P

KCD2-SCD-Ex1.ES

KCD2-SCD-Ex1.ES.SP

KCD2-SCD-Ex1

KCD2-SCD-Ex1.SP

KFD2-CD-Ex1.32


In Stock Pepperl+Fuchs KFD2-SCD2-Ex1.LK SMART Current Driver

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Payment Methods