Signal Conditioners and Modules
Pepperl+Fuchs KFD2-UFT-2.D Frequency Converter with Direction and Synchronization Monitor

Pepperl+Fuchs KFD2-UFT-2.D Frequency Converter with Direction and Synchronization Monitor

Model: KFD2-UFT-2.D

Supplier: Pepperl+Fuchs

Categories: Signal Conditioners and Modules

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KFD2-UFT-2.D Frequency Converter with Direction and Synchronization Monitor

Rotation Speed Monitor

General specifications

Signal type Digital Input

Supply

Connection terminals 23+, 24- or power feed module/Power Rail

Rated voltage 20 ... 30 V DC

Rated current approx. 130 mA

Power dissipation 2.2 W

Power consumption 2.5 W

Interface

Programming interface programming socket

Input

Connection side field side

Connection input I: terminals 1+, 3-

input II: terminals 4+, 6-

input III: terminals 13+, 14- (control input 1)

input IV: terminals 15+, 14- (control input 2)

Input I, II 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact

Open circuit voltage/short-circuit current 8.2 V / 10 mA

Switching point/switching hysteresis logic 1: > 2.5 mA ; logic 0: < 1.9 mA

Pulse duration min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs

Input frequency rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz

Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 4 mA

Input III, IV

Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA

Open circuit voltage/short-circuit current 18 V / 5 mA

Output

Connection side control side

Connection output I: terminals 10, 11, 12

output II: terminals 16, 17, 18

output III: terminals 19+, 20-

output IV: terminals 21+, 20-

output V: terminals 7-, 8+

Output I, II signal, relay

Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A

Mechanical life 5 x 107 switching cycles

Energized/De-energized delay approx. 20 ms / approx. 20 ms

Output III and IV signal , electronic output, passive

Contact loading 40 V DC

Signal level 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)

0-signal: blocked output (off-state current ≤ 10 µA)

Output V analog

Current range 0 ... 20 mA or 4 ... 20 mA

Open loop voltage max. 24 V DC

Load max. 650 Ω

Fault signal downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43)

Collective error message Power Rail

Transfer characteristics

Input I and II

Measurement range 0.001 ... 1000 Hz

Resolution slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz

Accuracy slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz

Measuring time frequency measurement: < 100 ms

Influence of ambient temperature 0.003 %/K (30 ppm)

Output I, II

Response delay ≤ 200 ms

Output V

Resolution < 10 µA

Accuracy < 30 µA

Influence of ambient temperature 0.005 %/K (50 ppm)

Galvanic isolation

Input I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Input III, IV/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output III, IV/power supply and collective error basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output III, IV/input III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output III, IV/V basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output V/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Interface/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Interface/output III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Indicators/settings

Display elements LEDs , display

Control elements Control panel

Configuration via operating buttons

via PACTware

Labeling space for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Low voltage

Directive 2014/35/EU EN 61010-1:2010

Conformity

Electromagnetic compatibility NE 21:2006

Degree of protection IEC 60529:2001

Input EN 60947-5-6:2000

Ambient conditions

Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protection IP20

Connection screw terminals

Mass 300 g

Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2

Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001


Similar model numbers:

KFD2-DWB-1.D

KFD2-SR2-2.W.SM

KFD2-UFC-1.D

KFD2-UFT-2.D

KFU8-DW-1.D

KFU8-DWB-1.D

KFU8-UFC-1.D

KFU8-UFT-2.D

KFU8-UFC-1.D.FA


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods