Schneider Electric ATS22C14S6 soft starter-ATS22-control 220V-power 230V(37kW)/400...440V(75kW)/500V(90kW)
Main
Range of productAltistart 22
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationPumps and fans
Component nameATS22
Network number of phases3 phases
[Us] rated supply voltage230...600 V - 15...10 %
motor power kW37 kW 230 V
75 kW 400 V
75 kW 440 V
90 kW 500 V
Factory setting current124 A
power dissipation in W82 W for standard applications
Utilisation categoryAC-53A
Type of startStart with torque control (current limited to 3.5 In)
IcL starter rating140 A for connection in the motor supply line for standard applications
IP degree of protectionIP00
Complementary
Assembly styleWith heat sink
Function availableInternal bypass
Supply voltage limits195…660 V
supply frequency50...60 Hz - 10...10 %
Network frequency45...66 Hz
Device connectionIn the motor supply line
[Uc] control circuit voltage230 V - 15...10 % 50/60 Hz
Control circuit consumption20 W
Discrete output number2
discrete output typeRelay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
minimum switching current100 mA at 12 V DC (relay outputs)
maximum switching current5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs
Discrete input number3
discrete input type(LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
discrete input voltage24 V <= 30 V
discrete input logicPositive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
output current0.4...1 Icl adjustable
PTC probe input750 Ohm
Communication port protocolModbus
connector type1 RJ45
Communication data linkSerial
Physical interfaceRS485 multidrop
Transmission rate4800, 9600 or 19200 bps
Installed device31
protection typePhase failure: line
Thermal protection: motor
Thermal protection: starter
MarkingCE
Type of coolingForced convection
Operating positionVertical +/- 10 degree
Height356 mm
Width150 mm
Depth229.5 mm
Net weight18 kg
Motor power range AC-330…50 kW at 200…240 V 3 phases
55…100 kW at 380…440 V 3 phases
55…100 kW at 480…500 V 3 phases
Motor starter typeSoft starter
Environment
electromagnetic compatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
StandardsEN/IEC 60947-4-2
Product certificationsGOST
CCC
CSA
UL
C-Tick
vibration resistance1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6
shock resistance15 gn for 11 ms conforming to EN/IEC 60068-2-27
Noise level56 dB
pollution degreeLevel 2 conforming to IEC 60664-1
relative humidity0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation-10…40 °C (without derating)
40…60 °C (with current derating 2.2 % per °C)
Ambient air temperature for storage-25…70 °C
operating altitude<= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height25.0 cm
Package 1 Width33.0 cm
Package 1 Length41.0 cm
Package 1 Weight13.32 kg
Unit Type of Package 2P06
Number of Units in Package 24
Package 2 Height73.5 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight66.28 kg
Similar model numbers:
ATS22C11S6
ATS22C14S6
ATS22C17S6
ATS22C21S6
ATS22C25S6
ATS22C32S6
ATS22C41S6
ATS22C48S6
ATS22C59S6
ATS22D17S6
ATS22D32S6
ATS22D47S6
ATS22D62S6
ATS22D75S6
ATS22D88S6
Any questions, feel free to contact us
jeff@hkxytech.com jeff@whxyauto.com +86-15072331761