Pepperl+Fuchs KFD2-GUT-Ex1.D Temperature Converter with Trip Values
General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 23+, 24- or power feed module/Power Rail
Rated voltage 20 ... 30 V DC
Rated current approx. 100 mA
Power dissipation/power consumption ≤ 2 W / 2.2 W
Interface
Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3, 4, 6
RTD Pt100, Pt500, Pt1000, Ni100, Ni1000
Types of measuring 2-, 3-, 4-wire technology
Lead resistance max. 50 Ω
Measurement loop monitoring sensor breakage, sensor short-circuit
Thermocouples type B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
Cold junction compensation external and internal
Measurement loop monitoring sensor breakage
Potentiometer 0.8 ... 20 kΩ
Types of measuring 2-, 3-, 5-wire technology
Voltage 0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
Input resistance ≥ 250 kΩ (0 ... 10 V)
min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
Measuring current approx. 400 µA with resistance measuring sensor
Output
Connection side control side
Connection output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
output III: terminals 8+, 7-
Output I, II relay
Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III Analog current output
Current range 0 ... 20 mA or 4 ... 20 mA
Open loop voltage max. 24 V DC
Load max. 650 Ω
Fault signal downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
Collective error message Power Rail
Transfer characteristics
Deviation
Temperature effect Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
RTD max. 0.2 % of span
Thermocouples max. 10µV
deviation of CJC: ±0.8 K
Voltage 0.1 % of span
Potentiometer 0.1 % of span when < 5 kΩ
0.5 % of span when > 5 kΩ
Current output max. 20 µA
Sampling rate approx. 700 ms
Galvanic isolation
Input/Other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective error reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2007
Degree of protection IEC 60529:2001
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Similar model numbers:
KFD2-CRG2-Ex1.D
KFD2-GUT-Ex1.D
KFU8-CRG2-Ex1.D
KFU8-GUT-Ex1.D
KFD2-WAC2-Ex1.D
KFD2-WAC2-Ex1.D-Y1
Any questions, feel free to contact us
jeff@hkxytech.com jeff@whxyauto.com +86-15072331761