Intrinsic Safety Barriers
Pepperl+Fuchs KFD2-WAC2-Ex1.D-Y1 Strain Gauge Converter

Pepperl+Fuchs KFD2-WAC2-Ex1.D-Y1 Strain Gauge Converter

Model: KFD2-WAC2-Ex1.D-Y1

Supplier: Pepperl+Fuchs

Categories: Intrinsic Safety Barriers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KFD2-WAC2-Ex1.D-Y1 Strain Gauge Converter

Switch Amplifier9

General specifications

Signal type Analog input

Supply

Connection Power Rail or terminals 23+, 24-

Rated voltage 20 ... 35 V DC

Ripple within the supply tolerance

Power consumption max. 3 W

Interface

Connection Power Rail or terminals 19+, 20 GND, 21-

Type RS-485

Programming interface programming socket

Field circuit

Connection terminals 1+, 2-, 3+, 4-, 5+, 6-

Lead resistance max. 25 Ω per line

Input I

Connection terminals 1+, 2-

Sensor supply 1 ... 5 V

Connection terminals 3+, 4- (supply); 5+, 6- (signal)

Short-circuit current 50 mA

Load ≥ 116 Ω up to 5V, ≥ 85 Ω up to 4V

Input

Connection side field side

Connection Input I: terminals 1+, 2-; Input II: terminals 13+, 14-; Input III: terminals 15+, 14-

Programmable Tare 0 ... 500 % of span

Input I Signal, analog

Input signal -100 ... 100 mV

Input resistance > 1 MΩ for voltage measurement

Input II, III tare adjustment, calibration and zero

Open circuit voltage/short-circuit current 18 V / 5 mA

Active/Passive I > 4 mA/I < 1.5 mA

Output

Connection side control side

Connection Output I: terminals 10, 11, 12; Output II: terminals 16, 17, 18; Output III: terminals 7-, 8+, 9-

Output I, II Relay output

Contact loading 253 V AC/2 A/500 VA/cos φ min. 0.7; 40 V DC/2 A resistive load

Mechanical life 2 x 107 switching cycles

Output III Analog output

Current range -20 ... 20 mA

Load max. 550 Ω

Analog voltage output 0 ... ± 10 V; output resistance 500 Ω (bridge between terminal 7 and 9)

Analog current output 0 ... ± 20 mA or 4 ... 20 mA; load 0 ... 550 Ω (terminals 7 and 8)

Line fault detection downscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V)

Collective error message Power Rail

Transfer characteristics

Deviation

Resolution/accuracy ≤ ± 0.2 % incl. non-linearity and hysteresis

Temperature effect ≤ ± 0.01 %/K

Reaction time 150 ms

Galvanic isolation

Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I, II against eachother reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output III/Input II, III not available

Output III/Programming socket not available

Other circuits from each other functional insulation, rated insulation voltage 50 Veff

Indicators/settings

Display elements LEDs , display

Control elements Control panel

Configuration via operating buttons

via PACTware

Labeling space for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Low voltage

Directive 2014/35/EU EN 61010-1:2010

Conformity

Electromagnetic compatibility NE 21:2006

Degree of protection IEC 60529:2001

Ambient conditions

Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protection IP20

Connection screw terminals

Mass approx. 250 g

Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2

Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001


Similar model numbers:

KCD2-UT2-Ex1

KFD0-CC-Ex1

KFD0-TR-Ex1

KFD0-TT-Ex1

KFD2-GUT-Ex1.D

KFD2-PT2-Ex1

KFD2-PT2-Ex1-5

KFD2-UT2-Ex1

KFD2-UT2-Ex1-1

KFD2-UT2-Ex2

KFU8-GUT-Ex1.D

KFD2-WAC2-Ex1.D

KFD2-PT2-Ex1-1

KFD2-PT2-Ex1-4

KFD2-PT2-Ex1-6-Y112844

KFD2-PT2-Ex1-Y98312

KFD2-UT2-Ex2-1

KFD2-WAC2-Ex1.D-Y1


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods