Intrinsic Safety Barriers
Pepperl+Fuchs KCD2-STC-Ex1.2O SMART Transmitter Power Supply

Pepperl+Fuchs KCD2-STC-Ex1.2O SMART Transmitter Power Supply

Model: KCD2-STC-Ex1.2O

Supplier: Pepperl+Fuchs

Categories: Intrinsic Safety Barriers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KCD2-STC-Ex1.2O SMART Transmitter Power Supply

Switch Amplifier8


General specifications

Signal typeAnalog input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 9+, 10-

Rated voltage19 ... 30 V DC

Ripplewithin the supply tolerance

Power dissipationapprox. 1.4 W at 20 mA transfer current, 250 Ω in both outputs

Power consumption2 W

Input

Connection sidefield side

Connectionterminals 1+, 2- (sink); 3+, 4- (source)

Input signal0/4 ... 20 mA

Voltage dropterminals 3, 4: ≤ 6.1 V at 20 mA

Short-circuit currentterminals 1+, 2-: 25 mA

Input resistanceterminals 1+, 2-: max. 500 Ω (BRAIN)

(250 Ω load)

Available voltageterminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA

Output

Connection sidecontrol side

Connectionsource: terminals 5-, 6+; 7-, 8+

sink: terminals 5+, 6-, 7+, 8-

Loadchannel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)

channel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)

Output signal0/4 ... 20 mA or 0/1 ... 5 V

Ripplemax. 50 µA rms

Transfer characteristics

DeviationIout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V

Influence of ambient temperaturecurrent output: 0.25 µA/K

voltage output: 80 µV/K

Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB)

control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB)

Settling time6 ms

Rise time/fall time2 ms

Galvanic isolation

Output/power supplyfunctional insulation, rated insulation voltage 50 V AC

Output/Outputfunctional insulation, rated insulation voltage 50 V AC

Indicators/settings

Display elementsLED

Control elementsDIP switch

Configurationvia DIP switches

Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2012

EN 61326-3-2:2008

Degree of protectionIEC 60529:2001

Protection against electrical shockUL 61010-1:2012

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions

Mechanical specifications

Degree of protectionIP20

Connectionscrew terminals

Massapprox. 100 g

Dimensions12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2

Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001


Similar model numbers:

KCD2-STC-Ex1.2O

KCD2-STC-Ex1.2O.ES

KCD2-STC-Ex1.ES

KFD2-CRG2-Ex1.D

KFD2-HLC-Ex1.D

KFD2-HLC-Ex1.D.2W

KFD2-STC5-Ex1

KFD2-STC5-Ex1.2O

KFD2-STC5-Ex1.2O.H

KFD2-STC5-Ex1.H

KFD2-STC5-Ex2

KFU8-CRG2-Ex1.D

KCD2-STC-Ex1-Y1

KCD2-STC-Ex1.ES.SP

KFD2-STC4-Ex1.2O-Y1

KFD2-STC4-Ex2-Y1

KCD2-STC-Ex1.2O.DE

KFD2-HLC-Ex1.D.4S

KCD2-STC-Ex1

KCD2-STC-Ex1.SP

KFD2-STC4-Ex1

KFD2-STC4-Ex1-Y1

KFD2-STC4-Ex1.2O

KFD2-STC4-Ex1.H

KFD2-STC4-Ex2

KFD2-STC4-Ex1.2O.H

KFD2-STV4-Ex1-1

KFD2-STV4-Ex1-2

KFD2-STV4-Ex1.2O-1

KFD2-STV4-Ex1.2O-2

KFD2-STV4-Ex2-1

KFD2-STV4-Ex2-2

KFD2-STV5-Ex1-1


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods