Intrinsic Safety Barriers
Pepperl+Fuchs KFD2-SOT3-Ex2.IO-Y1 Switch Amplifier

Pepperl+Fuchs KFD2-SOT3-Ex2.IO-Y1 Switch Amplifier

Model: KFD2-SOT3-Ex2.IO-Y1

Supplier: Pepperl+Fuchs

Categories: Intrinsic Safety Barriers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KFD2-SOT3-Ex2.IO-Y1 Switch Amplifier

Switch Amplifier

General specifications

Signal type Digital Input

Functional safety related parameters

Safety Integrity Level (SIL) SIL 2

Supply

Connection Power Rail or terminals 14+, 15-

Rated voltage 19 ... 30 V DC

Ripple ≤ 10 %

Rated current 30 ... 20 mA

Power dissipation ≤ 1.1 W including maximum power dissipation in the output

Input

Connection side field side

Connection terminals 1+, 2+, 3-; 4+, 5+, 6-

Rated values acc. to EN 60947-5-6 (NAMUR), see manual for electrical data

Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA

Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA

Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA

Pulse/Pause ratio min. 100 µs / min. 100 µs

Output

Connection side control side

Connection output I: terminals 7, 8 ; output II: terminals 10, 11

Rated voltage 30 V DC

Rated current 2 mA , short-circuit protected

Response time ≤ 200 µs

Signal level 1-signal: switching voltage - 0.85 V max. at 2 mA switching current

0-signal: switched off (off-state current ≤ 10 µA)

Output I signal ; Transistor , TTL compatible

Output II signal ; Transistor , TTL compatible

Collective error message Power Rail

Transfer characteristics

Switching frequency ≤ 5 kHz

Galvanic isolation

Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/Output basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff

Indicators/settings

Display elements LEDs

Control elements DIP switch

Configuration via DIP switches

Labeling space for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibility NE 21:2012 , EN 61326-3-2:2008

Degree of protection IEC 60529:2001

Input EN 60947-5-6:2000

Ambient conditions

Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protection IP20

Connection screw terminals

Mass approx. 150 g

Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2

Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Similar model numbers:

KCD2-SOT-Ex1.LB

KCD2-SOT-Ex2

KCD2-ST-Ex2

KFA5-SR2-Ex1.W

KFA5-SR2-Ex1.W.LB

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFD2-ER-Ex1.W.LB

KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP

KFD2-SOT3-Ex1.LB

KFD2-SOT3-Ex1.LB.IO

KFD2-SOT3-Ex2

KFD2-SOT3-Ex2.IO

KFD2-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFD2-SR2-Ex2.W

KFD2-SR3-Ex2.2S

KFD2-SRA-Ex4

KFD2-ST3-Ex1.LB

KFD2-ST3-Ex2

KHA6-SH-Ex1

KCD2-SON-Ex1

KCD2-SOT-Ex2.SP

KCD2-SR-Ex1

KCD2-SR-Ex1.LB

KCD2-SR-Ex1.LB.SP

KCD2-SR-Ex2

KCD2-SR-Ex2.SP

KCD2-ST-Ex1.LB

KFA5-SR2-Ex2.W

KFD2-DU-Ex1.D

WE 77/Ex-1 115V

WE 77/Ex-1 230V

WE 77/Ex-2 115V

WE 77/Ex-2 230V

KCD2-SON-Ex1.R1

KCD2-SON-Ex1.R2

KCD2-SON-Ex1.R3

KCD2-SON-Ex1.SP

KCD2-SON-Ex2

KCD2-SON-Ex2.R1

KCD2-SON-Ex2.R2

KCD2-SON-Ex2.R3

KCD2-SON-Ex2.SP

KCD2-SOT-Ex1.LB.SP

KCD2-ST-Ex1.LB.SP

KCD2-ST-Ex2.SP

KFA4-SR2-Ex2.W

KFA5-DU-Ex1.D

KFA5-SOT2-Ex2

KFA5-SR2-Ex2.W.IR

KFA6-DU-Ex1.D

KFD2-ELD-Ex16

KFD2-SOT3-Ex2.IO-Y1

KFA4-SR2-Ex1.W

KFA4-SR2-Ex1.W.LB

KFD2-SR2-Ex2.2S

KFD2-SOT2-Ex2.IO-Y181008

KFD2-BR-1.PA.1500


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods