Intrinsic Safety Barriers
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifier, Timer Relay

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifier, Timer Relay

Model: KFD2-DU-Ex1.D

Supplier: Pepperl+Fuchs

Categories: Intrinsic Safety Barriers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifier, Timer Relay

Switch Amplifier4


General specifications

Signal typeDigital Input

Supply

ConnectionPower Rail or terminals 23+, 24-

Rated voltage20 ... 30 V DC

Rated currentapprox. 100 mA

Power consumption1.8 W

Input

Connection sidefield side

ConnectionInput I: terminals 1+, 3- ; input II: terminals 13+, 14-

Input Iacc. to EN 60947-5-6 (NAMUR), see manual for electrical data

Open circuit voltage/short-circuit current8.2 V / 10 mA

Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA

Pulse durationmin. 75 µs / 1 ms see instruction manuals; the maximum input frequency has to be observed.

Input frequency0 ... 80 Hz , pulse divider 0 ... 1 kHz

Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 6.5 mA

Input IIreset

Active/PassiveI > 4 mA/I < 1.5 mA

Open circuit voltage/short-circuit current18 V / 5 mA

Pulse durationmin. 10 ms

Output

Connection sidecontrol side

Connectionoutput I: terminals 10, 11, 12 ; output II: terminals 19+, 20-

Output Isignal , Relay output

Contact loading253 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A

Mechanical life5 x 107 switching cycles

Energized/De-energized delayapprox. 20 ms / approx. 20 ms

Output IIsignal , electronic unit, isolated

Contact loading40 V / 50 mA

Energized/De-energized delayafter rising input flank 3 ms ; after falling input flank 2 ms

Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)

0-signal: blocked output (off-state current ≤ 10 µA)

Transfer characteristics

Input I

Resolution< 0.1 % of the set value, min. 10 ms

Accuracy2 ms

Influence of ambient temperature0.003 %/K (50 ppm)

Galvanic isolation

Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I/power supply and resetreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output II/power supply and collective errorbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output II/resetbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Reset/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Indicators/settings

Display elementsLEDs , display

Control elementsControl panel

Configurationvia operating buttons

Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Low voltage

Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21:2006

Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20

Connectionscrew terminals

Massapprox. 300 g

Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2

Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001


Similar model numbers:

KCD2-SOT-Ex1.LB

KCD2-SOT-Ex2

KCD2-ST-Ex2

KFA5-SR2-Ex1.W

KFA5-SR2-Ex1.W.LB

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFD2-ER-Ex1.W.LB

KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP

KFD2-SOT3-Ex1.LB

KFD2-SOT3-Ex1.LB.IO

KFD2-SOT3-Ex2

KFD2-SOT3-Ex2.IO

KFD2-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFD2-SR2-Ex2.W

KFD2-SR3-Ex2.2S

KFD2-SRA-Ex4

KFD2-ST3-Ex1.LB

KFD2-ST3-Ex2

KHA6-SH-Ex1

KCD2-SON-Ex1

KCD2-SOT-Ex2.SP

KCD2-SR-Ex1

KCD2-SR-Ex1.LB

KCD2-SR-Ex1.LB.SP

KCD2-SR-Ex2

KCD2-SR-Ex2.SP

KCD2-ST-Ex1.LB

KFA5-SR2-Ex2.W

KFD2-DU-Ex1.D

WE 77/Ex-1 115V

WE 77/Ex-1 230V

WE 77/Ex-2 115V

WE 77/Ex-2 230V

KCD2-SON-Ex1.R1

KCD2-SON-Ex1.R2

KCD2-SON-Ex1.R3

KCD2-SON-Ex1.SP

KCD2-SON-Ex2

KCD2-SON-Ex2.R1

KCD2-SON-Ex2.R2

KCD2-SON-Ex2.R3

KCD2-SON-Ex2.SP

KCD2-SOT-Ex1.LB.SP

KCD2-ST-Ex1.LB.SP

KCD2-ST-Ex2.SP

KFA4-SR2-Ex2.W

KFA5-DU-Ex1.D

KFA5-SOT2-Ex2

KFA5-SR2-Ex2.W.IR

KFA6-DU-Ex1.D

KFD2-ELD-Ex16

KFD2-SOT3-Ex2.IO-Y1

KFA4-SR2-Ex1.W

KFA4-SR2-Ex1.W.LB

KFD2-SR2-Ex2.2S

KFD2-SOT2-Ex2.IO-Y181008

KFD2-BR-1.PA.1500


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods