Switch Amplifier

General specifications

Signal type Digital Input

Supply

Connection Power Rail or terminals 14+, 15-

Rated voltage 19 ... 30 V DC

Ripple ≤ 10 %

Rated current 45 ... 70 mA

Power dissipation 1.2 W

Input

Connection side field side

Connection terminals 1-, 2+, 3-; 4-, 5+, 6-

Rated values acc. to EN 60947-5-6 (NAMUR), see manual for electrical data

Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA

Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA

Pulse/Pause ratio min. 35 ms / min. 35 ms (non-AC operation) min. 70 ms / min. 70 ms (AC operation)

Line fault detection breakage I ≤ 0.15 mA , short-circuit I > 6 mA

Output

Connection side control side

Connection output I: terminals 7, 8 ; output II: terminals 8, 9 ; output III: terminals 10, 11 ; output IV: terminals 11, 12

Output I ... IV Signal I ... Signal IV ; relay

Contact loading 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load;

Energized/De-energized delay approx. 30 ms / approx. 30 ms

Mechanical life 5 x 106 switching cycles

Collective error message Power Rail

Transfer characteristics

Switching frequency ≤ 10 Hz (non-AC operation) ≤ 3 Hz (AC operation)

Galvanic isolation

Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/Output basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elements LEDs

Control elements DIP switch

Configuration via DIP switches

Labeling space for labeling at the front

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Low voltage

Directive 2014/35/EU EN 61010-1:2010

Conformity

Electromagnetic compatibility NE 21:2006

Degree of protection IEC 60529:2001

Input EN 60947-5-6:2000

Ambient conditions

Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protection IP20

Connection screw terminals

Mass approx. 150 g

Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2

Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Similar model numbers:

KCD2-SOT-Ex1.LB

KCD2-SOT-Ex2

KCD2-ST-Ex2

KFA5-SR2-Ex1.W

KFA5-SR2-Ex1.W.LB

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFD2-ER-Ex1.W.LB

KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP

KFD2-SOT3-Ex1.LB

KFD2-SOT3-Ex1.LB.IO

KFD2-SOT3-Ex2

KFD2-SOT3-Ex2.IO

KFD2-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFD2-SR2-Ex2.W

KFD2-SR3-Ex2.2S

KFD2-SRA-Ex4

KFD2-ST3-Ex1.LB

KFD2-ST3-Ex2

KHA6-SH-Ex1

KCD2-SON-Ex1

KCD2-SOT-Ex2.SP

KCD2-SR-Ex1

KCD2-SR-Ex1.LB

KCD2-SR-Ex1.LB.SP

KCD2-SR-Ex2

KCD2-SR-Ex2.SP

KCD2-ST-Ex1.LB

KFA5-SR2-Ex2.W

KFD2-DU-Ex1.D

WE 77/Ex-1 115V

WE 77/Ex-1 230V

WE 77/Ex-2 115V

WE 77/Ex-2 230V

KCD2-SON-Ex1.R1

KCD2-SON-Ex1.R2

KCD2-SON-Ex1.R3

KCD2-SON-Ex1.SP

KCD2-SON-Ex2

KCD2-SON-Ex2.R1

KCD2-SON-Ex2.R2

KCD2-SON-Ex2.R3

KCD2-SON-Ex2.SP

KCD2-SOT-Ex1.LB.SP

KCD2-ST-Ex1.LB.SP

KCD2-ST-Ex2.SP

KFA4-SR2-Ex2.W

KFA5-DU-Ex1.D

KFA5-SOT2-Ex2

KFA5-SR2-Ex2.W.IR

KFA6-DU-Ex1.D

KFD2-ELD-Ex16

KFD2-SOT3-Ex2.IO-Y1

KFA4-SR2-Ex1.W

KFA4-SR2-Ex1.W.LB

KFD2-SR2-Ex2.2S

KFD2-SOT2-Ex2.IO-Y181008

KFD2-BR-1.PA.1500


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods