Intrinsic Safety Barriers
Pepperl+Fuchs KFD2-BR-1.PA.1500 Basic Segment Coupler

Pepperl+Fuchs KFD2-BR-1.PA.1500 Basic Segment Coupler

Model: KFD2-BR-1.PA.1500

Supplier: Pepperl+Fuchs

Categories: Intrinsic Safety Barriers

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

Pepperl+Fuchs KFD2-BR-1.PA.1500 Basic Segment Coupler

KFD2-BR-1.PA.1500

General specifications

Design / MountingCabinet installation

Supply

ConnectionPower Rail or terminals 11 (L+), 12 (L-)

Rated voltage20 ... 30 V DC

Ripple≤ 10 %

Rated current640 mA ... 365 mA

Power dissipationmax 2.5 W

Fieldbus connection

PROFIBUS PA

Connection3+, 6+, 2-, 5-, 1 shield, 4 shield

Rated voltage24 ... 26 V

Rated currentmax. 400 mA

Terminating impedance100 Ω , integrated

PROFIBUS DPPROFIBUS with RS-485 transmission technology

Connectionterminals 7 RxD/TxD-P, 8 RxD/TxD-N, 9 shield, 10 FE

Baud rate1.5 MBit/s max.

Indicators/operating means

SwitchPROFIBUS DP terminator

LED PWRgreen: Power on

LED DP/ERRred 2 Hz flashing: DP error red on: Hardware error red off: DP communication detected

LED PAred 2 Hz flashing: No PA communication or overload Off: PA communication OK

Galvanic isolation

PROFIBUS DP/PROFIBUS PAfunctional insulation acc. to IEC 62103, rated insulation voltage 50 V AC /70 V DC

PROFIBUS DP/Supplybasic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC

PROFIBUS PA/Supplybasic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Electromagnetic compatibilityNAMUR NE 21

Degree of protectionIEC/EN 60529

Fieldbus standardEN 50170/2

Climatic conditionsDIN IEC 721

Shock resistanceEN 60068-2-27

Vibration resistanceEN 60068-2-6

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)

Storage temperature-40 ... 85 °C (-40 ... 185 °F)

Relative humidity< 95 % non-condensing

Shock resistance15 g 11 ms

Vibration resistance1 g 10 ... 150 Hz

Pollution degreemax. 2, according to IEC 60664

Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Connection typeTerminals

Core cross sectionup to 2.5 mm2

Housing materialPolycarbonate

Degree of protectionIP20

Mass180 g

MountingDIN rail mounting


Similar model numbers:

KCD2-SOT-Ex1.LB

KCD2-SOT-Ex2

KCD2-ST-Ex2

KFA5-SR2-Ex1.W

KFA5-SR2-Ex1.W.LB

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFD2-ER-Ex1.W.LB

KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP

KFD2-SOT3-Ex1.LB

KFD2-SOT3-Ex1.LB.IO

KFD2-SOT3-Ex2

KFD2-SOT3-Ex2.IO

KFD2-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFD2-SR2-Ex2.W

KFD2-SR3-Ex2.2S

KFD2-SRA-Ex4

KFD2-ST3-Ex1.LB

KFD2-ST3-Ex2

KHA6-SH-Ex1

KCD2-SON-Ex1

KCD2-SOT-Ex2.SP

KCD2-SR-Ex1

KCD2-SR-Ex1.LB

KCD2-SR-Ex1.LB.SP

KCD2-SR-Ex2

KCD2-SR-Ex2.SP

KCD2-ST-Ex1.LB

KFA5-SR2-Ex2.W

KFD2-DU-Ex1.D

WE 77/Ex-1 115V

WE 77/Ex-1 230V

WE 77/Ex-2 115V

WE 77/Ex-2 230V

KCD2-SON-Ex1.R1

KCD2-SON-Ex1.R2

KCD2-SON-Ex1.R3

KCD2-SON-Ex1.SP

KCD2-SON-Ex2

KCD2-SON-Ex2.R1

KCD2-SON-Ex2.R2

KCD2-SON-Ex2.R3

KCD2-SON-Ex2.SP

KCD2-SOT-Ex1.LB.SP

KCD2-ST-Ex1.LB.SP

KCD2-ST-Ex2.SP

KFA4-SR2-Ex2.W

KFA5-DU-Ex1.D

KFA5-SOT2-Ex2

KFA5-SR2-Ex2.W.IR

KFA6-DU-Ex1.D

KFD2-ELD-Ex16

KFD2-SOT3-Ex2.IO-Y1

KFA4-SR2-Ex1.W

KFA4-SR2-Ex1.W.LB

KFD2-SR2-Ex2.2S

KFD2-SOT2-Ex2.IO-Y181008

KFD2-BR-1.PA.1500


Any questions, feel free to contact us

jeff@hkxytech.com   jeff@whxyauto.com   +86-15072331761

Related Products

Payment Methods